Re: how to solve disadvantages of installing esxi on sd card?

$
0
0

okay~!

it seemed that SD card and USB drives couldn't survive long being an ESXi boot disk due to current technological limitations.

i was thinking about using SATADOM as boot device could be a compromise between life span, performance, management and the simplicity of preserving logs.(comparing to others)

 

final question, does anyone know how frequent is the ESXi write logs to the partition?


Sync folders to OneDrive using VMware DEM/UEM

$
0
0

We are testing UEM/DEM and FSLogix on Horizon and have a use case to sync folders like My Documents etc. to OneDrive. We were using computer configuration policy "Silently move Windows known folders to OneDrive" (Use Group Policy to control OneDrive sync settings - OneDrive | Microsoft Docs) to achieve this, but with UEM/DEM, is there a better way of doing this? As you can see, this is a computer policy and since UEM/DEM handles only user policies I was wondering whether we can get rid of this GPO and achieve this via DEM.

 

Any thoughts?

Re: Live class - more info

Re: VUM with custom vendor images

$
0
0

anyone able to provide any feedback on my query?

 

Let me know in case you need more information

Re: Move to a vSphere 7 environment - recommended approach

$
0
0

Will there be any issue with the upgrade process if the license (VCSA/ESXi) is still for v6 and then its upgraded/applied post-upgrade? (as one of them has to come first)

 

Thanks

Re: VMWare vCenter cannor run power-on script successfully

$
0
0

Hi Lalegre,

 

I go to "Troubleshooting Mode" of my vCenter 6.0 VM console. Then I choose "Enable BASH Shell" and I click ENTER.
You can see the attached screenshot. After that I login with SSH client to the vCenter VM. I run the shell command.
I receive the message "Shell is disabled". Then I run the command shell.set --enabled True . I receive "Unknown command".

 

Can you please tell me how I can enable the Bash Shell and execute Linux commands ?

Windows10のsysprepファイルをVvCenter Server Applianceサーバに配置方法

$
0
0

vShere Client 6.7 からWIndows10を新規で作成後、テンプレート化したあと、カスタマイズ仕様を使って4台ほど、デプロイしようと思っています。vmware関連の書籍で、Windows10のSysprep.exeファイルをVvCenter Server Applianceサーバに配置する必要があると記載されていたのですが、どこに配置すればよいでしょうか

カスタマイズ仕様作成では、Sysprep.exeファイルを配置するような記載はありませんでした。そもそも、Sysprep.exeの配置は不要でしょうか。

Re: VMware and cisco cml 2

$
0
0

Would you please disable the "Virtualize Intel VT-x/EPT or AMD-V/RVI" the "in the "VM Setting -- > Processor" and have a try?


Workstation Player 15.5.6 disappears at power on, Linux Mint 20

$
0
0

I just installed VMWare Workstation 15 Player, 15.5.6 build-16341506 on Linux Mint 20. During creation of the virtual machine VMWare would not recognize my OS ISO file, so I selected the install OS later option. Later when I tried to power on the virtual machine to install my OS I briefly see a "waiting for connection" message then VMWare immediately closes. It never powers on.

 

I've never used VMWare before, so I don't know where I'm going wrong. Is it my machine not configured correctly (most likely) or is it a problem with VMWare?

Re: iSCSI sharing between two separately managed clusters

$
0
0

Thanks André

 

Just in case anyone else is looking for the solution on a QNAP device.

 

Initially I looked at having multiple targets and allowing connections to specified IQN's and mapping LUN's to targets. This seemed to work however there was a big problem in that on the QNAP you cannot modify the allowed IQN's list on a target while there are any devices connected to that target which is a bit unpractical in a production environment.

 

Following on from your suggestion I did a bit of more digging around I found the required function under "iSCSI ACL" on the QNAP device, this allows you to set RO, RW or Deny permissions to individual IQN's on a per LUN basis. This seems to hide the "denied" LUNS from ESXi hosts and can be modified while ESXi host is connected to target.

Re: ESXi 7.0 installer not detecting LSI 9240-8i RAID controller

$
0
0

Well I did a bit of digging, and it's not detecting because there aren't actually entries in LSI_MR3 for the 9240-8i

 

According to the KB page, it should be a "VMware Inbox, Native" driver and come bundled with 7.0

My test install of 7.0b reported the version that's supposedly required "7.712.50.00-1vmw.700.1.0.15843807"

VMware Compatibility Guide - I/O Device Search

 

Digging through LSI_MR3.map and lsi_mr3.ids I do not see it listed, The only thing remotely close is the Perc H310

 

 

regtype=native,bus=pci,id=1000005f10281f4e......,driver=lsi_mr3

regtype=native,bus=pci,id=1000007310281f4e......,driver=lsi_mr3

regtype=native,bus=pci,id=1000007310281f50......,driver=lsi_mr3

regtype=native,bus=pci,id=1000007310281f51......,driver=lsi_mr3

regtype=native,bus=pci,id=1000007310281f52......,driver=lsi_mr3

regtype=native,bus=pci,id=1000007310281f53......,driver=lsi_mr3

regtype=native,bus=pci,id=100000ce..............,driver=lsi_mr3

 

I'd expect to see 1000007310009240 in there.

 

I wonder what would happen if I forcefully added the HWids into the LSI_MR3 tables, using the following guide as a reference....

https://polarclouds.co.uk/esxi7-missing-percs/

Re: iSCSI vs NFS

$
0
0

Based on your attached document, there is many other factors that represent the iSCSI is better than the NFS in some cases, like the following list:

1. VMware PSA and load-balancing feature that is enable for the iSCSI, FC & FCoE, not the NFS.

2. iSCSI supports CHAP for authentication and improving the security.

3. Raw Device Mapping (RDM) feature is not supported by the NFS, but the iSCSI can do.

4. Boot from SAN is possible via the iSCSI not the NFS.

But regardless of comparing storage protocols, in many situations you can obtain benefits of both iSCSI and NFS. Ease of implementing and configuration for the NFS is a good characteristic but for the most of advanced features there are many shortcoming, especially in the lower versions of the NFS.

Re: VMvisor installer ISO for 6.7 update01 upgrade.  Does this installer also handle ver. 5.5?

$
0
0

Hi Cko001,

 

You can download the ESXi 5.5 iso from the vmware patch downloader page.

Link:

https://my.vmware.com/group/vmware/patch#search

Please look the below kb for the right build and then search using the same build number to get the iso download link.

 

 

Regards,

Sudeshna Sarkar

Install-Upgrade Specialist

Re: Move to a vSphere 7 environment - recommended approach

$
0
0

Hi andvm,

 

You should be able to upgrade the environment to 7.0 with the existing 6.x licenses as after the upgrade the vc as well as the esxi will be using evaluation license which will remain valid for 60 days.

During this 60 days period you can switch the license any time.

 

 

Regards,

Sudeshna Sarkar

Install-Upgrade Specialist

Re: ESXi 7.0 installer not detecting LSI 9240-8i RAID controller

$
0
0

I tried adding it to the LSI_MR3 and no dice.

 

I'm going to go out on a limb and say that it's either falsely marked as compatible or there was some sort of retraction from lsi_mr3 at some point?


Re: VIO 7 VDS deployment does not finish

$
0
0

With VMware support and engineering we could solve this issue.

Our vCenter has a ID containing uppercase letters, the installer does not like this.

VMware enginneering provides me a patch to solve this, maybe they will fix it in a future version.

Re: Configure a third DNS entry?

$
0
0

is this still the only way to add a third DNS entry?

Import-vApp and vCenter Extension vService

$
0
0

I try to automate the installation of the vSphere replication appliance,

This appliance needs to bind with the "vCenter Extension vService".

Wit the UI this works as expected, but is this registration also possible within the deployment with powercli?

Re: Replace Certificate on ESXi 6.7 Host

$
0
0

thanks will check it out.

 

Interested to know how many people actually apply certs to their ESXi hosts?

Re: VMWare vCenter cannor run power-on script successfully

$
0
0

To be easier for you please follow the next procedure: https://vsaiyan.info/2018/01/09/solved-vcenter-appliance-root-partition-100-full-plus-unable-to-log-in-to-the-root-accou…

 

Maybe the log to clean is not the same but it will help you entering the GRUB and do the cleanup. Also the Enable BASH Shell is to access the console from inside vCenter, not to login using SSH. So if inside the console you trigger Alt + F1 you will jump to the BASH Console.

 

However i still think that you need to follow the procedure mentioned above as you probably will not be able to login there also because of the root parition being full.

Re: Moving to pfSense Destroyed homelab VCSA?

$
0
0

All point that the resolution is not working but from inside the VCSA. Did you update the DNS Servers to be pointing to the pfSense after doing that change?

 

I never used pfSense in such way but why wouldn't you use the Domain Controllers as your DNS Servers configured on all the components.

Re: How to check ospf/BGP using Vshpere web client portal

$
0
0

Just to summarize a little bit, you can use the next commands:

 

show ip bgp neighbor summary to see the status of the configured neighbors

show ip route bgp to see the learned routes.

debug ip bgp to see the handshake between neighbors and possible errors (Disable and enable BGP on the Edge to get the logs)

 

Regards!


Re: VUM with custom vendor images

$
0
0

Hello andvm,

 

Yes they are applicable. I recommend you to always go to the newly version of ESXi using the Custom ISO and after doing that proceed with the installation of the patches.

 

Regards!

Re: dir-cli failed, error= Could not connect to the local service VMware AFD. Verify VMware AFD is running. 1021

$
0
0

How exactly are you running those command using PowerShell?

 

Could you show us the script itself and the execution of it?

Horizon 7 Upgrade to Horizon 8

$
0
0

How do I upgrade my Horizon 7 Enterprise license so I can use it with Horizon 8?

Re: Import-vApp and vCenter Extension vService

File lock error messages in log when browsing shared iSCSI datastore

$
0
0

Hi All,

 

I am new to using ESXi hosts on shared iSCSI datastore but pretty much have everything up and running however I am noticing a strange issue when browsing the files on the shared datastore.

 

When I browse the files on the datastore it takes ages to show the files when I switch between folders. If I go in to the events log on one of the hosts I see a heap of file lock errors logged.

 

Lock(s) held on file XXXXXXXX-ctk.vmdk by other host(s).

Exclusive Lock(s) held on a file on volume 5f2e9bde-d7f37ea2-2151-a0369f8af178. numHolders: 0. gblNumHolders: 0. Locking Host(s) MAC: xx:xx:xx:xx:xx:xx

 

it basically repeats these two error messages in the event log for every file in the folder.

 

The MAC address appears to be that of the host that is currently running the VM for whose folder I am browsing so that host having a lock on the files is normal I would think.

 

Am I correct in assuming that vCenter uses only one of the hosts in the cluster as a proxy to browse the iSCSI datastore? My reasoning is that all these errors only appear in only one hosts event log. If I down that particular host the events then appear in one of the other hosts events. I noted that if I browse folders for a VM that is running on the host that is currently proxying the errors do not appear and they directory loads instantly.

 

Is this normal behavior or have I got something not set correctly?

 

Everything else seems to run fine and there are no other errors other than these when I browse the datastore. It does not stop me from browsing the datastore it just takes a long time to load directory.

 

Thanks,

Steve.

ESXi консоль гипервизора

$
0
0

Здравствуйте

 

Помогите, пожалуйста.

То ли кнопки какие нажал не те, то ли после "игр" с переменной VMkernel.boot.Hyperthreadingmitigation теперь консоль гипервизора выглядит так

IMG_20200817_090430.jpg

 

вместо привычной

IMG_20200817_090406.jpg

 

хотя при нажатии F2 появляется окно запроса пароля

IMG_20200817_090437.jpg

далее все в порядке, а при выходе (ESC) опять темный экран со строкой про VMkernel.boot.Hyperthreadingmitigation

 

Подскажите, пожалуйста, может какие комбинации клавиш есть документированные ( и не только)

 

С уважением, Павел

Re: Import-vApp and vCenter Extension vService

$
0
0

Thank you!

Then I will try the way with ovftools.


Re: 6.0 to 6.7 Missing Dependency VIBs error - how to see if in use?

$
0
0

Hi Jacob29,

 

 

Please let me know the command that you are using to perform the esxi upgrade.

 

 

Regards,

Sudeshna Sarkar

Install-Upgrade Specialist

Re: Error "Unable to Connect to MKS" after upgrade to VMware Workstation 15.5.5

$
0
0

Come back after vacation and this CRITICAL bug is still not resolved? Even after more than 10 weeks...

 

Re: Horizon client with touch screen input

$
0
0

You may increase the scale of Linux OS.

Re: Device Updates for iOS

$
0
0

It doesnt matter which option i take, i can schedule it under the device update section, it works for some devices but not all of them. Pushing it directly to a specific device doesnt always work either.


We only have a few supervised devices so far, my thinking was to have a restriction profile with 30 days os update delay for example while beeing able to override those 30 days with a scheduled update assigment.

 

It happens for multiple iPhones aswell as iPads.

Re: No storage replication adapters installed.

$
0
0

Hi, i ran again into problems, but that was an issue because the VSC was down. I was missing my storage under the VSC tab of the vsphere client. When the VSC rebooted, and the storage was back, i noticed that the SRA was not enabled under settings > manage capabilities.

 

I have enabled the SRA again and things are running now. Because of a changed storage password i have added the storage again but forgot to enable SRA. We need this capability turned on for SRA to work.......

 

Thanks for your support!

Re: No storage replication adapters installed.

$
0
0

Great work there. Thank you for sharing the details

NSX-T 3.0 Design Suggestion

$
0
0

Hello Experts, Here is the point of discussion.

 

Customer wants to segregate the NS and EW traffic in NSX-T env and had enough 10 gig pnics available. We had proposed following.

 

2 for - VDS (mgmnt,vmotion)

2 for - NVDS1 - for workload VM's

2 for - NVDS2 - for DMZ workload ....

 

But in this design, Edge VM will sit on Host NVDS and will consume 2 nics for overlay as well as N-S.

 

If we design it as per the customer requirement, its like going back to old 2.4 edge VM design where Edge had multiple nvds and was possible to assign individual pnics for e-w and n-s using named teaming policy. This design is still possible in 2.5 & 3.0, however pnics assigned to N-S traffic on the host where there is no edge VM, will be ideal until an edge vm moves to that host..? so what is the point in keeping pnics unused..?

 

Comments please.


Re: dir-cli failed, error= Could not connect to the local service VMware AFD. Verify VMware AFD is running. 1021

$
0
0

PFA script to create a user in vCenter.

ESxI 6.7 И USB 3.0 проблемы с цифровыми ключами

$
0
0

Есть виртуальный сервер c Windows Server 2016 стоит на ESXi 6.7

Служит в качестве терминального сервера для 1С 8.2

Так вот поступила задача собрать все электронные ключи цифровой подписи от (Avest AvPass) и установить их на сервер, в результате ключей собралось 7 штук плюс ключ(аппаратный) от 1С (Aladdin Knowledge Sentinel HL). Купили USB - Hub на семь портов плюс в сервере два вроде хватило.

Но после того как подключаешь USB-Hub сервер начинает жутко тормозить из-за ключей с хабом. При этом ключи работают.

Причем тормозит из-за того что в диспетчере устройств они постоянно по очереди обновляются, то нормально по проблема с драйвером. При поиске ошибок иногда пишет что usb 3.0 controller xHCI не может правильно работать с устройством USB 2.0.

Пробовал ставить оба контроллера в настройках виртуалки usb 2.0 controller и usb 3.0 controller все равно тормозит с теми же симптомами плюс и начинает намертво зависать раз в пару дней. Один раз оставил машину только с ключом от 1С и usb 2.0 controller раз в сутки машина зависала на мертво с usb 3.0 controller нормально.

 

Еще один вариант делал ставил хаб на свой комп и пробрасывал ключи с помощью USB Network Gate v8.0.1828 то работает нормально,но это вариант не подходит.

Re: NMP: nmp_ResetDeviceLogThrottling in vmkernel log

$
0
0

The Log is Full from those Logs , I changed the naa GUUID .

 

 

 

2020-08-17T06:49:33.656Z cpu2:2098268)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcda from world 2100373 to dev "naa.60060160c9f149" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.660Z cpu2:2098268)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcdc from world 2100373 to dev "naa.60060160ee2048" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.664Z cpu10:2098270)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcde from world 2100373 to dev "naa.60060160c9f14" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.667Z cpu2:2098268)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xce0 from world 2100373 to dev "naa.60060160c9f149" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.671Z cpu2:2098268)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xce2 from world 2100373 to dev "naa.60060160ee2048" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.676Z cpu10:2098270)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xce4 from world 2100373 to dev "naa.60060160c9f14" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.680Z cpu10:2098270)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xce6 from world 2100373 to dev "naa.60060160c9f14" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.686Z cpu2:2098268)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xce8 from world 2100373 to dev "naa.60060160c9f149" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.693Z cpu2:2098268)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcea from world 2100373 to dev "naa.60060160c9f149" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.697Z cpu2:2098268)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcec from world 2100373 to dev "naa.60060160ee2048" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.708Z cpu10:2098270)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcee from world 2100373 to dev "naa.60060160c9f14" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.712Z cpu10:2098270)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcf0 from world 2100373 to dev "naa.60060160ee204" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

2020-08-17T06:49:33.722Z cpu10:2098270)ScsiDeviceIO: 3469: Cmd(0x459bce3f6a00) 0x85, CmdSN 0xcf2 from world 2100373 to dev "naa.60060160c9f14" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x20 0x0.

Re: ESxI 6.7 И USB 3.0 проблемы с цифровыми ключами

$
0
0

Добрый день!

 

При таком количестве рекомендую посмотреть в сторону решений USB over IP, чем решать проблемы работы хаба (который опционально стоит попробовать в других портах).

 

По поводу USB over IP пример решений:

- Digi anywhereUSB

- SEH

vRealize Automation 8.1 - Issue specifying network to connect vNIC

$
0
0

Hey folks,

 

I am facing an issue where i cannot specify to which network connect the newly deployed VM. I tried the next:

 

  • Using hard constraint tag.
  • Specify the network to connect using a tag.

 

I tried multiple combination of those tags on the Network object and also on the Machine object but always it is selecting one default network. I already checked that the network does not have the "Default Zone Network" check.

 

Any clues?

Using older clients with Horizon 8

$
0
0

With the release of Horizon 2006 we are obviously looking at upgrading from our 7.12 environment. Currently checking all the pre-requisites prior to upgrade (note! you need at least a 2012 domain functional level for Horizon 2006!), I've been playing with the product interoperability matrix, and have noticed that (if this is correct) none of the previous client releases are supported with Horizon 2006. Is this really the case?  Do we have to upgrade all of the clients before we can roll this out?

 

We do have some older thin clients which only have the 4.7 client on and these work fine with 7.12 (albeit with some features not available), will these continue to work?

 

Cheers

 

JD

Re: NSX-T 3.0 Design Suggestion

$
0
0

If the version is 3.0 with vSphere 7.0 ,VDS 7.0 . You can follow below approach

 

2 for - VDS01 (mgmnt,vmotion)

2 for - VDS02 - for workload VM's with Edges

2 for - VDS03 - for DMZ workload with DMZ edges

 

As far traffic segregation , above design is not enough .They would need unique uplink connectivity to unique TOR L3 and FW, sometimes people collapse the physical layer (DMZ&DC)  with micro segmentation on DMZ workloads which is also fine.  On a side note, uplink utilization of NIC totally depends on DRS nature of movement that will kick Edges or VM to different host, something which we ideally don't control it ( exceptions are DRS rules) , so i'm unsure why we should worry about this point. If you have equal number of servers and tenants with Edges with A-A and A-S config , for sure utilization will there on all PNICS for all servers.


Re: Live class - more info

$
0
0

Live online classes are instructor-led, so yes it should.

Re: Workstation Player 15.5.6 disappears at power on, Linux Mint 20

$
0
0

Please post a screenshot of the "waiting for connection" message.

Re: App install failed when started by AW Catalog

$
0
0

Hello everyone,

 

now, i know that other admin has the same problem.

 

 

kind regards

Benjamin

Re: Moving to pfSense Destroyed homelab VCSA?

$
0
0

Moderator: Thread moved to the vCenter Server area.

Re: How to make ssh to embedded vRO in vRA 8.1 ?

$
0
0

Hi, Almost, I have tried to all commands syntax. But, it does not work. If you tried before could you send me full command ?

Re: ESXi консоль гипервизора

$
0
0

Модератор: Тема перенесена в русскую зону

Re: Workstation Player 15.5.6 disappears at power on, Linux Mint 20

$
0
0

It took some doing, but I finally got a shot. Once I click "power on" this screen only comes up for less than a tenth of a second before VMWare closes.

 

(Hopefully I attached the picture correctly.)